Applies to: HP Proliant Servers
Error: BMC Event Log Full
Use below steps to resolve issue
- Proceed to BIOS
- Advanced Menu-> IPMI-> System Event Log
- Change the value for Clear System Event Log to Enabled
- Press F10 and restart the server
Applies to: HP Proliant Servers
Error: BMC Event Log Full
Use below steps to resolve issue
Some of you may have faced this problem while configure a new Dell server. Even though you meet the hardware pre-requisites like minimum 3 HDD etc. for configuring RAID 5, yet the server will show only RAID 0 and RAID 1 options.
The below steps will illustrate how we can enable RAID 5 option for a Dell R510 Server.
If a foreign configuration is present in the server,Only RAID 0 and RAID 1 will be available and it will not allow you to configure in RAID 5.
Take a clear note that I am talking about a fresh configuration for a Dell Server. If you are facing this scenario in any other condition or while swapping/replacing HDDs from any other virtual configuration, then the reason may be different